Dexcom (Independent Publisher) (Preview)

This connector is used to retrieve Estimated Glucose Values (EGV) from the Dexcom Diabetes Continuous Glucose Monitor website.

This connector is available in the following products and regions:

Service Class Regions
Logic Apps Standard All Logic Apps regions except the following:
     -   Azure Government regions
     -   Azure China regions
     -   US Department of Defense (DoD)
Power Automate Premium All Power Automate regions except the following:
     -   US Government (GCC)
     -   US Government (GCC High)
     -   China Cloud operated by 21Vianet
     -   US Department of Defense (DoD)
Power Apps Premium All Power Apps regions except the following:
     -   US Government (GCC)
     -   US Government (GCC High)
     -   China Cloud operated by 21Vianet
     -   US Department of Defense (DoD)
Contact
Name Joe Unwin
URL https://www.flowjoe.io
Email [email protected]
Connector Metadata
Publisher FlowJoe
Website https://www.dexcom.com/
Privacy policy https://www.dexcom.com/linked/documentservice/PrivacyPolicy
Categories Data;Lifestyle and Entertainment

Throttling Limits

Name Calls Renewal Period
API calls per connection 100 60 seconds

Actions

Get EGVs

Estimated Glucose Value (EGV) Request from Dexcom

Get EGVs

Estimated Glucose Value (EGV) Request from Dexcom

Parameters

Name Key Required Type Description
startDate
startDate string

The start date that will be used to for the Estimated Glucose Value (EGV) readings.

endDate
endDate string

The end date that will be used to for the Estimated Glucose Value (EGV) readings. This has a maximum of 90 days.

Returns

Name Path Type Description
unit
unit string

unit

rateUnit
rateUnit string

rateUnit

egvs
egvs array of object

The /egvs endpoint enables retrieval of a user's estimated glucose value (EGV) data, including trend and status information.

systemTime
egvs.systemTime string

Time according to the system clock at which observation was made; nominally UTC

displayTime
egvs.displayTime string

Time displayed on the receiving device when the observation was made

value
egvs.value integer

Estimated glucose value

realtimeValue
egvs.realtimeValue integer

Estimated glucose value presented on receiving device in realtime

smoothedValue
egvs.smoothedValue string

Estimated glucose value presented retrospectively on receiving device after smoothing; G6 devices only

status
egvs.status string

Explanation of EGV record; used when the value field is outside the measuring range

trend
egvs.trend string

General trend of EGV value movement; corresponds to trendRate field

trendRate
egvs.trendRate float

Rate at which glucose value is moving up or down